+41 31 990 00 70

The new TA16 is similar to the TA2, but has been specially developed for noise-sensitive applications where a small, compact linear drive is required (e. g. medical and furniture technology). The slim electric cylinder is optionally available with protection class IP66 and/or Hall sensor as incremental encoder.

Features

• very low noise

• small size for easy installation

 

Voltage: 12 V DC, 24 V DC
Load max.: 3500 N pression / 2500 N tension*
Lifting speed max.: 23.5 mm/s idle speed, 13.5 mm/s full load*
Stroke: 20~1000 mm
Min. installation length: stroke length + 112 mm
Ambient temperature: +5° C – + 45° C
Limit switches: integrated
Hall sensor (option): 1 K or 2 K
Protection class: IP54 (IP66 Option) 
Standards, directives: IEC60601-1, ES60601-1, RoHS

 

*depending on the gear ratio and the motor

 

Subject to technical changes and errors excepted.